If your QIDI Plus4 runs V1.6.0 and the chamber stays cold at the start of a print, check the bed first. In V1.6.0, QIDI says chamber heating waits until the bed reaches its specified temperature. If the Plus4 chamber stays cold or your Q1 Pro reports a chamber heating fault, save the temperatures and any error message for QIDI. Plus4 V1.6.0 release notes · QIDI after-sales support
If the printer produces smoke, power it off immediately and contact QIDI. QIDI safety guidance
Check the bed and chamber temperatures
- Open the thermals chart in Fluidd. Click the bed and chamber heater names if their traces are hidden. Fluidd Thermals
- If the failed attempt is still in the chart history, capture the bed and chamber traces with their targets. Copy any error shown by the printer. Fluidd Thermals · QIDI’s support evidence requirements
- Use the readings to decide what to report.
| What you see | What to check or send |
|---|---|
| Plus4 on V1.6.0, bed still below its specified temperature | QIDI lists reaching the specified bed temperature as a condition for chamber heating to start. If the bed reaches it and the chamber stays cold, send both traces. V1.6.0 release notes |
| Plus4 or Q1 Pro, chamber target reads zero | Look earlier in the chart for a nonzero target during the failed attempt. Include the target trace with your report. Fluidd Thermals · QIDI after-sales support |
| Plus4 or Q1 Pro, chamber below its target when a heating-rate error appears | Send the trace and full error. Both published configurations include a chamber heater check. QIDI’s Klipper code can shut the printer down when the measured temperature fails that check. Plus4 configuration · Q1 Pro configuration · QIDI heater verification code |
Report a board LED you already saw
If you already observed a motherboard or solid-state relay (SSR) LED, tell QIDI which board it was on, its color, whether it was steady, blinking or dark, and what the chamber target was at the time. Ask support to interpret the observation. Include an existing photo if it shows the symptom. QIDI after-sales support
Confirm the replacement part with QIDI
- Plus4. QIDI’s October 2024 reply in the Plus4 SSR issue directed owners who needed a replacement for that issue to after-sales support. Ask whether a revised SSR board is available for your unit and which part QIDI recommends for your symptom. QIDITECH reply in issue 15
- Q1 Pro. Use the Q1 Pro contact in QIDI’s support policy. Ask support to identify the correct part from the fault and temperature readings. QIDI after-sales support
Send the request to Plus4support@qidi3d.com for a Plus4 or Q1support@qidi3d.com for a Q1 Pro. Include proof of purchase, the model, the bed and chamber targets and readings, and the exact error if one appears. Attach any chart capture or other evidence you already have. QIDI after-sales support · QIDI’s support evidence requirements
Evidence note. The checks were drawn from QIDI’s Plus4 V1.6.0 release notes, the published Plus4 and Q1 Pro configurations, QIDI’s support pages and Fluidd’s thermals guide. The steps were not run on either printer.